Indoor air quality monitoring: a practical guide for facility teams.

Published October 10, 20265 min read
Milvian AI teamFacilities and infrastructure intelligence
Ceiling air unit under a glass roof

Indoor air quality monitoring is the continuous measurement of CO2, particulates, VOCs, temperature and humidity in occupied spaces, so ventilation can be adjusted before people are affected. Good monitoring reads every zone continuously, ties readings to occupancy, and links each finding to a ventilation action that can be verified.

What indoor air quality monitoring is for

Indoor air quality monitoring answers a simple question: is the air in this space fit for the people in it, right now? A one-off survey cannot answer that, because indoor air changes by the hour. It changes with occupancy, with cleaning schedules, with outdoor conditions, with process activity and with how the ventilation system is actually running.

Continuous monitoring turns air from an assumption into a measurement. It shows when a space goes out of range, how long it stays there, and what was happening at the time. That is what lets a facility team move from reacting to complaints to fixing the cause.

What to measure

Most programs start with a core set of parameters, then add more where the space demands it.

ParameterWhat it tells youTypical cause when high
CO2Whether ventilation keeps up with occupancyToo little outdoor air for the number of people
PM2.5 and particulatesFine particles that reach the lungsOutdoor pollution, combustion, process dust
VOCsGases from products and materialsCleaning products, new furnishings, solvents
Temperature and humidityComfort, and conditions for moldControl faults, setpoint drift, poor dehumidification
Carbon monoxideCombustion gases indoorsVehicles, generators, faulty appliances
OccupancyWhether anyone is there to be affectedThe context every other reading needs

Why CO2 matters, and what it does not tell you

People exhale CO2, so in an occupied room it rises when ventilation does not bring in enough outdoor air. That makes CO2 a practical proxy for ventilation performance. It is cheap to measure, it responds quickly, and it gives a clear signal to act on: when CO2 climbs in an occupied space, bring in more fresh air.

CO2 is not the whole picture. A well-ventilated room can still carry particulates from outside or VOCs from a cleaning crew. Monitoring programs that only read CO2 miss those events. The better approach is a sensor set matched to the space: CO2 and temperature everywhere, particulates near entrances, loading docks and process areas, VOCs where products and materials are a concern.

Where sensors go, and how to trust them

Each air sensor speaks for a limited area, so the building should be divided into zones that a single sensor can represent. Mount sensors at breathing height in the occupied part of the room, away from supply diffusers, open windows, doors and direct breath, where a draft or a single person can skew the reading. Large open spaces need more than one sensor. Small rooms with high occupancy, such as meeting rooms and classrooms, usually need their own.

Sensor health is part of data quality. A sensor with a weak connection or a failing battery produces gaps and false readings that look like real events. A monitoring program should report each sensor's connection rate and battery or supply voltage, so the team knows which device needs attention before it trusts the data, and knows exactly where that device is without walking the site.

Finally, keep the history. Air quality questions often arrive after the fact: a complaint, an audit, a certification review. A continuous record by zone, with occupancy alongside, answers them with evidence instead of memory.

Duration and occupancy change the answer

For indoor air, how long a level lasts matters as much as how high it goes. A brief spike when a meeting room fills is a different problem from a level that holds for hours. That is why exposure is better tracked in zone-hours, the time each zone spends above a threshold, than as a single peak reading.

Occupancy is the other half. A CO2 event in an empty building does not matter. The same reading in a full classroom or a busy ward does. Overlaying air quality with occupancy shows when a problem actually affects people, in which zone, and starts the search for the cause. Patterns become visible too: a nightly VOC spike when the cleaning crew arrives, or high CO2 at a loading dock when trucks idle with engines running.

Snapshots can mislead. A survey taken on a quiet day, or a weekend with production stopped, can show air that looks fine and is not representative of a working day. Continuous monitoring shows the real curve.

Setting up a monitoring program

  1. Map the zonesDivide each floor into zones a sensor can speak for. Prioritize high-occupancy spaces, process areas and known complaint spots.
  2. Choose the parametersCO2, temperature and humidity everywhere. Add particulates, VOCs or CO where the space needs them.
  3. Add occupancyFrom sensors or a schedule, so every reading is read in context.
  4. Set targets by space typeUse the standard or certification that applies to you, and check the current rule before you set a threshold.
  5. Link findings to actionEach breach should lead to a ventilation change or a ticket, then a reading that confirms the zone is back in range.

Fixing air without burning energy

The easy answer to poor air is more outdoor air all the time. That costs energy, because every extra unit of outdoor air has to be heated, cooled or dehumidified. Demand-controlled ventilation is the better answer: raise outdoor air when CO2 and occupancy say a zone needs it, and lower it when the zone is empty. Using an economizer when outdoor conditions are mild makes the extra air cheap.

Aqueduct runs this as a loop. Zone sensors and occupancy feed a live view of each site. When a zone breaches, Aqueduct names the cause in plain language, references the standard behind the rating, and recommends the action, such as increasing ventilation or checking the AHU economizer. Where control is enabled and approved, it adjusts ventilation directly. The next readings verify the zone is back in range. Healthy air on Aqueduct is powered by aQ AirSafe.

ASHRAE 62.1ASHRAE 55WELL Building StandardRESET AirEPA IAQ Tools for SchoolsASHRAE 241OSHA permissible exposure limits
Questions

Questions about this topic

At minimum CO2, temperature and humidity. Add particulates, VOCs and carbon monoxide where the space, its occupants or its processes call for them.

It is a good measure of ventilation relative to occupancy. It does not capture particulates or VOCs, so it should not be the only parameter.

Enough that each zone has a sensor that can speak for it. High-occupancy rooms and process areas usually need their own.

Not if ventilation follows demand. Demand-controlled ventilation adds outdoor air when a zone needs it and cuts it when the zone is empty.

It depends on the building type and region. ASHRAE 62.1 is widely used for ventilation in the US, and certifications such as WELL and RESET Air set their own criteria. Check the current rule that applies to you.