GHG Protocol

GHG Protocol Scope 1 and 2, measured from the meter up

The GHG Protocol Corporate Standard is the most widely used method for corporate greenhouse gas inventories. Scope 1 covers direct emissions such as on-site fuel combustion, and Scope 2 covers purchased electricity, steam, heat and cooling, reported location-based and market-based. Aqueduct supplies the activity data: metered fuel and electricity by site, with factors recorded and a trail from meter to total.

Powered by aQ EnergySmart, built on aQ Core
Condenser fans seen from above
Site performance · this quarter
-8.4% vs expected
Weather normalizedBelow baseline
Demo data
Peak demand today
612 kW
Contracted 650 kWChillers sequenced
Demo data

What the GHG Protocol asks for in Scope 1 and 2

The Greenhouse Gas Protocol, developed by the World Resources Institute and the World Business Council for Sustainable Development, sets the global accounting standards behind most corporate carbon reporting. The Corporate Standard asks a company to set an organizational boundary using equity share, financial control or operational control, set an operational boundary across scopes, choose a base year and keep a consistent inventory. Frameworks such as CDP, CSRD, SECR, BRSR and ISSB build on it.

Scope 1 is direct emissions from sources the company owns or controls, such as boilers, generators, furnaces, company vehicles and refrigerant leaks. Scope 2 is indirect emissions from purchased electricity, steam, heat and cooling. The Scope 2 Guidance requires dual reporting: a location-based figure using grid average factors and a market-based figure reflecting contracts and certificates. Emissions are activity data multiplied by emission factors, so the quality of activity data drives the quality of the inventory. The GHG Protocol is revising parts of its standards, so check the current guidance.

Evidence map

Scope 1 and 2 requirements and the evidence Aqueduct supplies

Aqueduct supplies measured activity data. Your carbon team owns boundaries, factors and the inventory.

RequirementEvidence neededHow Aqueduct supplies it
Stationary combustion (Scope 1)Fuel burned in boilers, generators and furnaces by siteGas meters, fuel flow meters and generator energy read per site and period
Refrigerants and vehicles (Scope 1)Refrigerant top-ups and vehicle fuelNot measured by Aqueduct; these come from service logs and fleet records
Purchased electricity (Scope 2)Consumption by site for the reporting periodUtility and sub-meters by site, with interval data and bills reconciled
Purchased heat, steam and cooling (Scope 2)Energy received from district systemsDistrict heating and cooling energy meters read over M-Bus or Modbus
Location-based factorsGrid average factors by regionGrid carbon factor applied per site, with source and year shown next to each figure
Market-based methodContractual instruments and residual mix factorsMetered consumption your team pairs with contracts and certificates
Base year and recalculationA consistent base year and records of structural changesHistorical data by site so the base year can be rebuilt when sites are added or sold
Data quality and verificationEvidence that activity data is complete and accurateCoverage, estimation flags and meter-to-total exports for your verifier
How it works

How to prepare a Scope 1 and 2 inventory for verification

01

Set the boundaries

Choose the consolidation approach and list every site and source in scope.

02

Build the source register

Map each emission source to a meter, a bill or a record. Aqueduct's meter register covers the metered sources.

03

Collect activity data

Pull energy and fuel by site for the year, with gaps and estimates flagged rather than hidden.

04

Apply factors and calculate

Record each factor's source and year, calculate location-based and market-based Scope 2 and total by scope.

05

Verify

Give your verifier the trail from meter readings to totals, with methods and assumptions documented.

What stays with your carbon team

An inventory is a set of decisions. Aqueduct supplies measured activity data.

Boundaries and methods

Consolidation approach, base year policy and factor choices are decisions your team documents.

Scope 3

Value chain emissions come from procurement, logistics and supplier data outside Aqueduct.

Verification

Third-party verifiers give assurance. Aqueduct does not verify inventories.

Standards and regulations

Related standards

Built on or alongside the GHG Protocol.

GHG Protocol Scope 2 GuidanceISO 14064-1CDPSECR ISSB IFRS S2SBTi
Trusted at scale
Read the case studies
Deployed275+

sites in 21 countries run on Aqueduct.

Healthcare22 hospitals

and 9 clinics in one of India’s top hospital chains.

AirportsTop 25

US airport running water intelligence on Aqueduct.

Real estate20M+ sq ft

of commercial real estate under Aqueduct.

Manufacturing300 acres

FMCG manufacturing campus.

Food and dairyMajor dairy

operations run on Aqueduct.

Questions

Common questions

Scope 1 is direct emissions from sources you own or control, such as boilers and generators. Scope 2 is indirect emissions from purchased electricity, steam, heat and cooling. Aqueduct meters the energy behind both.

Location-based uses average grid factors for where the energy is consumed. Market-based reflects the contracts and certificates you buy. The GHG Protocol asks for both.

Aqueduct applies grid carbon factors to metered electricity and shows carbon alongside energy, with the factor source and year. Your carbon team decides final factors and methods for the inventory.

No. Refrigerant emissions come from service records and top-up logs. Aqueduct can flag equipment behavior that suggests a refrigerant problem, but it does not measure refrigerant mass.

Bills can be late, estimated or cover odd periods. Metered data gives complete, period-aligned consumption by site, which improves accuracy and makes verification easier.

Yes. The GHG Protocol is revising parts of its standards, including Scope 2 guidance. Check the current status before you change methods.

See Aqueduct on your own facility.

Bring a site, a utility bill or a question. We will show you where the loss is.